Training: floorsBautec · Kiesel · BerryAlloc systems
--:--
Training partners BauTec – adhesives and lacquers Kiesel – adhesives on site BerryAlloc Only practice
Two-day plan

Training schedule

Click ▶ next to a section to start the countdown. When time is up, the timer plays a signal and announces the end of the section.

    Construction chemicals for floors

    Bautec and Kiesel products

    Primers, compounds, adhesives and care products used in the training. Data from the technical data sheets in the training materials 10.2026.

    BauTec Kiesel

    Permissible substrate moisture

    SubstrateUnheatedHeated
    Cement screed, concrete≤ 2.0% CM≤ 1.8% CM
    Anhydrite (calcium sulphate) screed≤ 0.5% CM≤ 0.3% CM
    Wooden substrate (Bautec)8–12%
    Wood and wood-based panels (BerryAlloc)max. 50% relative humidity
    Damp cement – barrier 2× TEC PRIMER PUup to 4.5% CM
    Barrier TEC PRIMER EPX / Okapox GFup to 6.0% CM

    Measured with the CM method or an electronic meter. Values from Bautec data sheets and BerryAlloc instructions.

    TKB notched trowels – selection

    TKB A2 trowel
    TKB A2Dispersion adhesives for dryback LVT, approx. 0.25–0.30 kg/m²
    TKB B2 trowel
    TKB B22K mineral adhesive, small parquet, 0.8–1.0 kg/m²
    TKB B9 trowel
    TKB B9Bonding onto self-levelling compound, tongue and groove
    TKB B15 trowel
    TKB B15HPF/Chateau panels on screed, long planks

    Adhesive consumption depends on the absorbency and evenness of the substrate. It increases on porous substrates.

    How to combine products

    Bonding systems Bautec · Kiesel

    Choose the floor type and substrate condition. The diagram shows the order of layers and the products in the 2K and 1K variants.

    Rough calculator

    How much material?

    Manufacturer installation instructions

    BerryAlloc – installation step by step

    Click a step to mark where the group is. For glue-down installation, the Bautec system recommendation is shown next to the instructions.

    BerryAlloc
    48 hacclimatisation in closed packs
    18–25 °Croom temperature (Zenn: 15–25 °C)
    40–60 %relative air humidity
    2.0 / 0.5% CM: concrete / anhydrite (heated 1.8 / 0.3)
    8–10 mmexpansion gap at walls – floating floor
    5 mmexpansion gap at walls – glue-down
    On-site documentation

    Bautec reports

    Report templates from the Bautec training manual 10.2026. Pick a report from the list. The “Print” button prints a blank A4 form. The forms themselves are in Polish.

    BauTec

    End of section